Current Transformers

    Inventory #

  CT1677

756X50G8

by

General Electric

Bar Style

Single Tap

C100 Relay Class

Low Voltage

all specifications...
  • 756X50G8 available as-is,
    or remanufactured
  • Remanufactured current transformer includes
    1 Year Parts & Labor Warranty
  • Large stock of 756X50G8 Replacement Parts
Product Photos
050 051 052 053 055 056

Current Condition

This photo shows a similar current transformer to CT1677, after it had undergone remanufacturing by
RESA Power. Actual photos of this 756X50G8 Bar Current Transformer in its current condition are shown above.

Detailed Specs
General Specifications

Manufacturer: General Electric

Catalog #: 756X50G8

Style: Bar


Power Information

Low Voltage

Relay Class: C100

Single Tap

Ratio: 100:5


Dimensions

Height: 16.00"

Width: 12.50"

Depth: 10.75"

Rectangle Style Current Transformer

Written Detailed Specification

General Electric 756X50G8 Bar Current Transformer with Window, low voltage, C100 relay class, single tap.


Warranty

RESA Power warranties this rebuilt General Electric 756X50G8 current transformer for one year, including all labor, freight and materials required to return it to operational standards. RESA Power guarantees this current transformer will operate to your satisfaction given competent supervision and normal load and usage conditions. Any repairs performed without the express written permission of RESA Power Inc. shall invalidate this warranty. RESA Power shall not be liable to the customer, or to any other person, for consequential damages, lost profits or other kinds of damages arising out of the sale or use of this current transformer.


The General Electric 756X50G8 from RESA Power

All General Electric 756X50G8 Bar Current Transformers can be purchased as remanufactured to factory standards (please see General Electric Current Transformer factory remanufacturing specification). You can also order your General Electric 756X50G8 Bar Current Transformer configured to your specified wiring diagrams. We also carry a large stock of replacement parts for the General Electric 756X50G8 Bar Current Transformer. Call one of our sales consultants today.

Remanufacturing
Current Transformer Remanufacturing


At RESA Power, we don’t just rebuild General Electric Instrumentation Transformers, we remanufacture them. All of our remanufactured General Electric 756X50G8 Current Transformers conform to NETA and ANSI C37 specifications, and all tolerances are checked to meet or exceed the original manufacturer’s specifications.


Warranty

RESA Power warranties this remanufactured General Electric 756X50G8 current transformer for one year, including all labor, freight and materials required to return it to operational standards. RESA Power guarantees this current transformer will operate to your satisfaction given competent supervision and normal load and usage conditions. Any repairs performed without the express written permission of RESA Power Inc. shall invalidate this warranty. RESA Power shall not be liable to the customer, or to any other person, for consequential damages, lost profits or other kinds of damages arising out of the sale or use of this current transformer.

Other Products
Similar Products to CT1677 (756X50G8)
Catalog Number Manufacturer Style Ratio(s) Relay Class
756X50G8 General Electric Bar 100:5 C100
671X21 General Electric Bar 40:5 C10
671X21 General Electric Bar 40:5 C10
671X21 General Electric Bar 40:5 C10
755X1G6 General Electric Bar 50:5 C10
755X42G8 General Electric Bar 50:5 C5
756X50G10 General Electric Bar 200:5 C30
756X50G10 General Electric Bar 200:5 C5
756X50G10 General Electric Bar 200:5 C30
756X50G10 General Electric Bar 200:5 C5
756X50G10 General Electric Bar 200:5 C30
756X50G10 General Electric Bar 200:5 C30
756X50G10 General Electric Bar 200:5 C30
756X50G10 General Electric Bar 200:5 C30
756X50G10 General Electric Bar 200:5 C5